PAK PS PY2 PSX
Linear potentiometric transducersPAK: aluminium case, mechanical anchor, dragging with shaft thread M6, strokes from 50 to 900 mm, connector 4 poles complying the DIN43650 norm (spherical joint M6 on request).
PY2: aluminium case, mechanical anchor, feeler shaft with double bearings and recall spring, push rod with threaded stem M2,5 and an inox steel sphere, connector 5 poles complying the DIN43322 norm. Strokes from 25 to 100 mm.
PS: aluminium case, anchor and self-alligned mechanical dragging on 2 spherical joints, max. motion angle to ±30°, strokes from 50 to 750 mm, connector 4 poles complying the DIN43650 norm.
PSX: aluminium housing with stainless steel shaft, easy mounting by the means of back-lash free pivot heads with a large angle of free movement up to ±12,5°. Resolution 0,01mm and linearity up to ±0,05%. Heavy duty and compact dimensions, makes this sensor suitable for use in environments with humidity, oil, dust, etc. This sensor is particularly recommended for mobile applications as in mechanical engineering, testing benches, etc.
➜The combining with a display (for ex. V3P, V4P, VE6P), makes of this device an economical, simple and effective system for the measuring of shiftings on machine tools, automatic-, wood-marble-glassworking machinery, etc., with an accuracy not higher than ±0,1 mm.
PAK | |||||||
Versions | PA50K | PA100K | PA200K | PA300K |
L: case lenght mm | 159 | 209 | 309 | 411 |
Useful electrical stroke mm | 51 | 102 | 204 | 304 |
Resistance KOhm | 2 | 3 | 5 | 5 |
Indipendent linearity % | 0,10 | 0,10 | 0,07 | 0,06 |
Versions | PA500K | PA600K | PA900K |
L: case lenght mm | 615 | 716 | 1021 |
Useful electrical stroke mm | 508 | 610 | 914 |
Resistenza KOhm | 5 | 5 | 5 |
Indipendent linearity % | 0,05 | 0,05 | 0,06 |
PS | |||||||
Versions | PS75 | PS100 | PS225 | PS300 | PS500 | PS750 | |
B: pivot distance mm | 247 | 273 | 400 | 476 | 730 | 1040 | |
Useful electrical stroke mm | 76 | 102 | 228 | 304 | 508 | 762 | |
Resistance KOhm | 3 | 3 | 5 | 5 | 5 | 10 | |
Indipendent linearity % | 0,10 | 0,10 | 0,07 | 0,06 | 0,05 | 0,04 |
PY2 | |||||||
Versions | PY2-25 | PY2-50 | PY2-75 | PY2-100 | |||
C: overall dimension | 137 | 193 | 258 | 315 | |||
Useful electrical stroke mm | 25 | 50 | 75 | 100 | |||
Resistance KOhm | 1 | 5 | 5 | 5 | |||
Indipendent linearity % | 0,20 | 0,15 | 0,10 | 0,075 |
PSX | |||||||
Versions | PSX-25 | PSX-50 | PSX-100 |
C: pivot distance mm | 128,5 | 153,5 | 203,5 |
Useful electrical stroke mm | 27 | 52 | 102 |
Resistance KOhm | 1 | 2 | 4 |
Indipendent linearity % | 0,20 | 0,10 | 0,10 |
Versions | PSX-175 | PSX-200 | PSX300 |
C: pivot distance mm | 294,5 | 319,5 | 419,5 |
Useful electrical stroke mm | 180 | 205 | 305 |
Resistance KOhm | 7 | 8 | 12 |
Indipendent linearity % | 0,05 | 0,05 | 0,05 |
The P Interface turns the signal supplied by a potentiometric transducer into current 0-20 mA, 4-20 mA or voltage 0-10Vdc.
Its typical employment is the current or voltage transmission of signals supplied by a remote potentiometric transducer to remote supervision systems.
Special features of the P interface are its low cost and simple setting: activating two trimmers it’s possible to refer the entire output range to the stroke of the poten-tiometer effectivly employed.
The instrument is carried out in a 3-module case for assembling on DIN EN50022 guide.
VERSIONS
VERSIONS | |
INTP0 | Power supply 115Vac |
INTP1 | Power supply 230Vac |
INTP2 | Power supply 24Vac |
INTP3 | Power supply 24Vdc |
TECHNICAL FEATURES | |
Input impedance | 1 Mohm |
Linearity | endless |
Max. load impedance for current output | 600 Ohm |
Min. load impedance for voltage output | 1Kohm |
Output resolution | 12 Bit |
Outputs | 0÷10 Vdc; 4÷20mA; 0÷20mA |
Potentiometer input | 1÷50 Kohm |
Power supply | 115Vac, 230Vac, 24Vac, 24Vdc 3VA |
Relative humidity | 10 ÷ 90 % |
Working temperature | ÷50°C |
EMC | 2014/30/UE |
RoHS |
2011/65/UE |
DIMENSIONS |
The instruments of the V_P series are multifunction microprocessor display units with input from potentiometric transducer that are particularly indicated for the measurement of linear and angular dimensions.
• V3P: the measured dimension may be compared with 3 intervention thresholds that may be set for the enabling of as many relays, the status of which is displayed through a led.
Versions: V3P- displayed, V3P-3 displayed with 3 intervention ON/OFF.
• V4P: the measured value can be compared with 2 or 3 alarms settable for enabling many relays whose status is displayed by LEDs. Two analog outputs, a voltage 0-10V or -10 to +10 V, the other 4 ÷ 20mA 12-bit resolution, and its possible to configure the instrument and check its status via serial interface RS485 with MODBUS RTU protocol.
➜ for more complete information, see sec. "Displays, impulse counters, positioning units, ..." in the drop-down menu on the left.
The P_X positioning units serie are programmable microprocessor single-axis positioner with relay or analogue outputs.
• P3X: processes signals provided by potentiometric position transducers linear or rotary. The 16-key keyboard with 6 operation indicators make it simple and easy to use and the setup of the positioner.
➜ for more complete information, see sec. "Displays, impulse counters, positioning units, ..." in the drop-down menu on the left.
Richiedi l'accesso
PAK PS PY2 PSX
Click here to download
PAK PS PY2 PSX
Click here to download
PAK PS PY2 PSX
Click here to download